COMPRISED SERIES
: KVV, KVV BS_1, KVV 40
-
APPLICATION
For Screw Compressors and Air System
- As a component of the idling bypass system
- To vent the pressure in the oil separator automatically on shut-down
-
OPERATION
Venting Valve is normally open in two ways without the return of spring. Open or Closed valve position is determined by the built-in Solenoid Valve action. Once the Venting Valve is signaled by the Solenoid, it starts to vent the unnecessarily remained pressure in the Air-End and the Separator.
-
INSTALLATION, CONTROL SYSTEM
Venting Valve is normally installed at the Suction Control Valve and controlled by the signal pressure for the capacity control downstream from the Solenoid Valve.
Model | KVV | KVV BS_1 | KVV 40 |
---|---|---|---|
Applied Horse Power (HP) | All | All | Less than 30HP |
Temperature Range (°C) | -20 ~ 100 | ||
Maximum Pressure (bar) | 16 | ||
Connections (A) | 15 | 15 | 8 |
Remarks | This is a standardized product applied for SUCTION VALVE. Alteration is impracticable, and for more information or requests about E-Catalogue, please contact to Overseas Sales Department. |